Technical Parameters:


Suitable valve size NPT/BSP 11/4",  NPT/BSP 11/2",  NPT/BSP 2" (Optional)
Maximum working pressure 1.0MPa
Circulation medium Fluid, Air
Rated voltage DC12V, DC24, AC/DC9-35V, AC110-230V(Optional)
Wiring control methods

CR2-01, CR2-02 , CR3-03, CR4-01, CR5-01, CR5-02, 

CR7-03, CR7-04 (Optional)

Working current ≤ 800MA
Open/close time ≤ 15 Sec
Life time 50000 times
Valve Body material Stainless Steel 304
Actuator material Engineering Plastics
Sealing material EPDM & PTFE
Actuator rotation 90°
Max. torque force 10 Nm
Cable Length 0.5m,1.5m (Optional)
Environment temperature -15℃~50℃
Liquid temperature 2℃~90℃
Manual override NO
Indicator Yes
Protection class IP67

Specifications:

Model Wiring control Working voltage Max. torque
A100 CR2 01

DC12V, DC24V

10Nm
A100 CR2 02 AC/DC9-35V 10Nm
A100 CR3 03 DC12V, DC24V 10Nm
A100 CR4 01 AC110-230V 10Nm
A100 CR5 01 DC12V, DC24V 10Nm
A100 CR5 02 AC/DC12-24V 10N.M
A100 CR7 03 DC12V, DC24V 10N.M
A100 CR7 04 AC110-230V 10N.M

Wiring diagram:

CR2 01 Wiring Diagram ( 2 wires control )

·RD connect with positive, the BK connect with negative, the valve closed, the actuator automatically power off after in place , the valve remains fully closed position
·BK connect with positive, the RD connect with negative, the valve open, the actuator automatically power off after in place, the valve remains fully open position .
﹡Suitable Working Voltage: DC5V/DC12V/DC24V

﹡Exceeding the working voltage is forbidden


CR2 02 Wiring Diagram ( 2 wires control  Spring return  in case of the power failure)     

·When SW is closed , the valve open. the actuator automatically power off after in place

·When SW is open, the valve closed, the actuator automatically power off after in place 
Suitable Working Voltage: AC/DC9-35V

Exceeding the working voltage is forbidden

CR3 03 Wiring Diagram (3 wires control)

·RD& GR connect with positive, the BK connect with negative。

·SW CLOSED, the valve OPEN,  the actuator automatically power off after in place

·SW OPEN, the valve CLOSED,  the actuator automatically power off after in place.

﹡Suitable Working Voltage: AC/DC9-35V/AC110-230V

﹡Exceeding the working voltage is forbidden


CR5 01 Wiring diagram ( with feedback signal)

1RD connect with positive, the BK connect with negativethe valve closed, the actuator automatically power off after in place .

BK connect with positive, the RD connect with negativethe valve open, the actuator automatically power off after in place .

3.BL & WT are connect when the valve open fully, YW & WT are connect when the valve closed fully

Suitable Working Voltage:DC12V,DC24V

Exceeding the working voltage is forbidden

CR502 Wiring Diagram ( 5 wires control – Spring return)

·When SW is closed , the valve open. the actuator automatically power off after in place

·When SW is open, the valve closed, the actuator automatically power off after in place   BL & WT are connect when the valve open fully, YW & WT are connect when the valve cl  osed fully

Suitable Working Voltage: AC/DC9-24VAC/DC110V-230V,

Exceeding the working voltage is forbidden


CR7 03 Wiring Diagram ( 7 wires control with feedback signal )

·RD& GR connect with positive, the BK connect with negative。

·SW CLOSED, the valve OPEN,  the actuator automatically power off after in place

·SW OPEN, the valve CLOSED,  the actuator automatically power off after in place.

·BL & GY connect with the valve’s fully open signal wiring 

·YW & WT connect with the valve’s fully closed signal wiring.

﹡Suitable Working Voltage: DC12V,DC24V

﹡Exceeding the working voltage is forbidden


CR7 04 Wiring Diagram ( 7 wires control with feedback signal )

·RD & BK are connected to the power, WT & YW are connected to the controlled wiring.

·When the SW is closed , the valve open 

·When the SW is open , the valve closed 

·BL & GY connect with the valve’s fully open signal wiring 

·YW & WT connect with the valve’s fully closed signal wiring.

Suitable Working Voltage:AC/DC110V-230V

Exceeding the working voltage is forbidden





Relative Products: