Welcome to Taizhou Tonhe Flow Control Co.,Ltd
Taizhou Tonhe Flow Control Equipment Co.,Ltd.

Products
Home > Products

A150-T32-S2-B DN32 SS304 SS316 motorized ball valve

>> A150-T32-S2-B DN32 SS304 SS316 motorized ball valve

Technical Parameters

Connection standard ISO5211 F03、F05
Output axis specification Female octagonal 9*9 or 11*11 Maximum working pressure
Max pressure



1.5MPa

Rated voltage

DC12V;  DC24V ; AC24V ;DC12-24V (Optional )
Wiring diagram CR201;CR202;CR301;CR303;CR306;CR501;CR502;CR702;CR703;CR706 (Optional)
Life time 70000 times(testing pressure is 0.4MPa, medium is water)
Actuator material Engineering Plastics PPO
Torque force 15NM
Cable Length 0.5m,1.5m
Environment temperature -15℃~60℃
Liquid temperature 2℃~90℃
Manual operation


Yes
Open/close indicator Yes
Protection class IP67
Company quality management system


ISO 9001:2015

Wiring diagram

CR2 01 Wiring Diagram ( 2 wires control )

·RD connect with positive, the BK connect with negative, the valve closed, the actuator automatically power off after in place , the valve remains fully closed position .

·BK connect with positive, the RD connect with negative, the valve open, the actuator automatically power off after in place, the valve remains fully open position .

Suitable Working Voltage: DC12V, DC24V

Exceeding the working voltage is forbidden

CR5015 wires controlwith feedback wire

  

1. RD connect with positive, the BK connect with negativethe valve closed, the actuator automatically power off after in place .

2  BK connect with positive, the RD connect with negativethe valve open, the actuator automatically power off after in place .

4.  GR & WT are connect when the valve open fully, YW & WT are connect when the valve closed fully

Suitable Working VoltageDC12V, DC24V

Exceeding the working voltage is forbidden
Feedback wire capacity:
1. Voltage: DC0-35v; 2. Maximum current: 0.4A


CR202 (2 wires control--- Reset function, Normally closed or normally open


·When SW is closed , the valve open. the actuator automatically power off after in place 

·When SW is open, the valve closed, the actuator automatically power off after in place
Suitable Working Voltage: AC24VDC12-24V

Exceeding the working voltage is forbidden
Please Note A150 CR202 must need charge time >1 minut for every time use


CR502 Wiring Diagram ( 5 wires control – Spring return)

·When SW is closed , the valve open. the actuator automatically power off after in place 

·When SW is open, the valve closed, the actuator automatically power off after in place

GR & WT are connect when the valve open fully, YW & WT are connect when the valve closed fully

Suitable Working Voltage: AC24VDC12-24V

Exceeding the working voltage is forbidden

Feedback wire capacity:
1. Voltage: DC0-35v; 2. Maximum current: 0.4A
Please Note A150 CR202 must need charge time >1 minut for every time use


CR301 Wiring Diagram 


·RD & GR connect with positive, BK connect with negative

·When OPEN( RD) & SW connected , the valve open, the actuator automatically power off after in place , valve remains fully open position

·When CLOSE(GR) & SW connected, the valve closed, the actuator automatically power off after in place, valve remains fully closed position.

Suitable Working Voltage: DC12V, DC24V,AC24v,DC12v-24v

Exceeding the working voltage is forbidden


CR7 02 Wiring Diagram ( 7 wires control with feedback signal )


1.RD & GR connect with positive, the BK connect with negative

2. When RD & SW connected, the valve open, the actuator automatically power off after the valve fully open.

3. When GR & SW connected, the valve closed, the actuator automatically power off after the valve fully closed,.

4. BL & GY connect with the valve’s fully open signal wiring

5. YW & WT connect with the valve’s fully closed signal wiring

Suitable Working Voltage: DC12V, DC24V,AC24v,DC12v-24v

Exceeding the working voltage is forbidden

Feedback wire capacity:
1. Voltage: DC0-35v; 2. Maximum current: 0.4A


CR3 03 Wiring Diagram (3 wires control )


·RD connect with positive, GR connect with SW & positive
·BK connect with negative
·When the SW of GR closed, the valve OPEN, the actuator automatically power off after in place , remains fully closed position
·When the SW of GR open, the valve CLOSED, the actuator automatically
power off after in place , remains fully open position.
﹡Suitable Working Voltage: DC12V, DC24V,AC24v,DC12-24v
﹡Exceeding the working voltage is forbidden

CR7 03 Wiring Diagram ( 7 wires control with feedback signal )


·RD& GR connect with positive, the BK connect with negative
·SW CLOSED, the valve OPEN, the actuator automatically power off after in place
·SW OPEN, the valve CLOSED, the actuator automatically power off after in place.
·BL & GY connect with the valve’s fully open signal wiring
·YW & WT connect with the valve’s fully closed signal wiring.
﹡Suitable Working Voltage: DC12V, DC24V,AC24V,DC12-24V
﹡Exceeding the working voltage is forbidden
Feedback wire capacity:
1. maximum voltage DC36V, AC220V; 2. maximum current 0.4 A.

CR3 06 Wiring Diagram ( 3 wires control – Power reset funtion)


1)Power off(failure), valve close
·RD& GR connect with positive, the BK connect with negative
·SW CLOSED, the valve close,  the actuator automatically power off after in place
·SW OPEN, the valve open,  the actuator automatically power off after in place.
Power off, valve close itself.

2)Power off(failure), valve open
·RD& GR connect with positive, the BK connect with negative
·SW CLOSED, the valve
open,  the actuator automatically power off after in place
·SW OPEN, the valve close,  the actuator automatically power off after in place.
Power off, valve open itself.
﹡Suitable Working Voltage: AC24V,DC12V-24V
﹡Exceeding the working voltage is forbidden

CR706(7 wires control)

1)Power off(failure), valve close
·RD& GR connect with positive, the BK connect with negative
·SW CLOSED, the valve close,  the actuator automatically power off after in place
·SW OPEN, the valve open,  the actuator automatically power off after in place.
Power off, valve close itself.

2)Power off(failure), valve open
·RD& GR connect with positive, the BK connect with negative
·SW CLOSED, the valve
open,  the actuator automatically power off after in place
·SW OPEN, the valve close,  the actuator automatically power off after in place.
Power off, valve open itself.

·BL & GY connect with the valve’s fully open signal wiring
·YW & WT connect with the valve’s fully closed signal wiring.
﹡Suitable Working Voltage: AC24V,DC12V-24V
﹡Exceeding the working voltage is forbidden


Relative Products: